RENAULT MASTER 3 2.3L dCi 107kW/143HP SID321

ECU CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL · 145 CV (107 kW) · 2300 cc · Diesel sovralimentato

ECU-databaseRENAULT › RENAULT MASTER 3 2.3L dCi 107kW/143HP SID321

Vind de firmware-identificatoren (hardware-, software- en updatenummers), beschikbare tuning-opties en hoe je het originele of geremapte bestand krijgt.

✓ Tuning via bestand (flash) 6 firmwareversies

Voertuiggegevens

MerkRENAULT
ModelMASTER 3
Motor2.3L dCi 107kW/143HP SID321
Standaard vermogen145 CV / 107 kW
Cilinderinhoud2300 cc
BrandstofDiesel sovralimentato
VoertuigtypeLCV

ECU

FabrikantCONTINENTAL-SIEMENS-VDO
ModelSID321_CONTINENTAL
Geheugen / EPROMMicro Infineon TRICORE categoria AURIX. Il micro ha una DFLASH da 848 Kbite

Beschikbare tuning-opties:

  • Boost pressure limiter for diagnostics
  • Boost pressure limiter
  • Boost pressure
  • Boost pressure in aftertreatment modes
  • Maximum torque limitation at clutch
  • Compressor pressure ratio limit for pumping and speed
  • Effective engine torque setpoint for safety
  • Exhaust gas temperature value before turbine in regeneration mode
  • Exhaust gas temperature value before turbine in regular injection mode
  • Max torque correction factor for APS sensor
  • Max torque correction factor for APS sensor in aftertreatment modes
  • Max torque correction factor for soot mass
  • Max torque correction factor for soot mass in aftertreatment modes
  • Max torque correction factor for IAT sensor
  • Max torque correction factor for IAT sensor in aftertreatment modes
  • Basic torque management at engine cranking
  • Injection efficiency
  • Injection opening time related to inj. pressure
  • Injection opening time related to inj. pressure 3
  • L
  • Torque limiter
  • Torque limiter in full load
  • Torque limiter in Eco mode
  • Smoke limiter
  • Smoke limiter in aftertreatment modes
  • RPM Limiter
  • RPM limiter - AT
  • RPM limit for ECT sensor
  • Maximum absolute effective torque
  • Max exhaust gas temperature value before turbine in regeneration mode
  • Max exhaust gas temperature value before turbine in regular injection mode
  • Max force table for force to powertrain setpoint conversion
  • Specific injection pressure limiter
  • Specific injection pressure limiter in aftertreatment modes
  • Maximum pressure ratio limit depending on temperature
  • Specific injection pressure
  • Specific injection pressure in aftertreatment modes
  • Air mass flow
  • Driver torque request
  • Driver torque request Dynamic mode
  • Torque value tolerance between level 1 and level 2
  • Torque value tolerance between level 1 and level 2 - AT
  • Torque limiter for the APS/BPS in aftertreatment modes
  • Torque limiter in aftertreatment modes
  • Torque limiter in aftertreatment modes 2
  • Torque limiter for EFT sensor
  • Torque limiter in recovery mode
  • Torque model - fuel quantity to torque conversion
  • Torque model - fuel quantity to torque conversion 2
  • Torque model - fuel quantity to torque conversion in aftertreatment modes
  • Torque model - torque to fuel quantity conversion
  • Torque model - torque to fuel quantity conversion - particulate regeneration mode

Firmware-identificatoren (6)

Hardware-nr.Software-nr. (chip)VersieUpdate-softwareECU
237010374V 1.83.010237610377V CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL
237010374V 1.83.010237610393V CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL
237010374V 1.83.010237610375V CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL
237011330V 1.83.009237611346V CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL
237010374V 1.83.009237610390V CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL
237018559S 1.83.010237618812S CONTINENTAL-SIEMENS-VDO SID321_CONTINENTAL

ECU-notities

Microprocessor TC297TP_128 This Setting File can be used for serial system NewGenius.