PORSCHE CAYENNE (9PA) 3.0L V6 TDI 180kW/241HP EDC17CP44

ECU BOSCH EDC17CP44 · 245 CV (18 kW) · 3000 cc · Diesel sovralimentato

ECU duomenų bazėPORSCHE › PORSCHE CAYENNE (9PA) 3.0L V6 TDI 180kW/241HP EDC17CP44

Raskite programinės įrangos identifikatorius (aparatinės, programinės įrangos ir atnaujinimo numerius), galimas derinimo parinktis ir kaip gauti originalų arba perprogramuotą failą.

✓ Derinimas failu (flash) ✓ Galimas papildomas modulis 9 programinės įrangos versijos

Transporto priemonės duomenys

MarkėPORSCHE
ModelisCAYENNE (9PA)
Variklis3.0L V6 TDI 180kW/241HP EDC17CP44
Serijinė galia245 CV / 18 kW
Darbinis tūris3000 cc
KurasDiesel sovralimentato
Transporto priemonės tipasAuto

ECU

GamintojasBOSCH
ModelisEDC17CP44
Atmintis / EPROMMICRO ST TRICORE - 32768 Kbit - 400000

Galimos derinimo operacijos / parinktys:

  • Boost pressure limiter
  • Boost pressure
  • Protection for cylinder head overheating
  • Regeneration limit for DPF
  • Regeneration limit for DPF 2
  • EGR valve control
  • EGR valve control 2
  • EGR valve control 3
  • EGR valve control 4
  • EGR valve control 5
  • EGR valve control 6
  • EGR valve control 7
  • EGR valve control 8
  • Max accepted exhaust gas temperature value before turbine
  • Max accepted exhaust gas temperature value before turbine 2
  • Protection for engine overheating
  • Protection for engine overheating 3
  • Engine reference power at crankshaft
  • Basic torque management at engine cranking
  • Engine idle vs. ECT sensor
  • Injection period
  • Injection period 3
  • Injection period 4
  • Injection period 5
  • Injection period 6
  • Injection period 7
  • Injection period 8
  • Injection opening time related to inj. pressure
  • Injection opening time related to inj. pressure 2
  • Initialization values over pressure control valve
  • Injection 1
  • Injection 2
  • Torque limiter
  • Torque limiter for diagnostic
  • Torque limiter for diagnostic 2
  • Torque limiter during inactive pre-injection
  • Smoke limiter
  • RPM limit for ECT sensor
  • RPM limit for ECT sensor 2
  • Lambda reference
  • Lambda value of the smoke limitation
  • Minimum LSU sensor temperature limit - heater control
  • Minimum LSU sensor temperature for O2
  • Maximum LSU sensor temperature limit - heater control
  • Maximum LSU sensor temperature for O2
  • LSU temperature setpoint
  • LSU temperature threshold PID heater governor activation
  • Speed limiter
  • Speed limiter - reverse gear
  • Maximum indicated torque
  • Maximum indicated torque for monitoring
  • Maximum engine torque at crank shaft
  • Protection for air load overheating
  • Protection for exhaust gas temperature before turbine
  • Protection for exhaust gas temperature before turbine 2
  • Protection for fuel overheating
  • Protection for fuel overheating 2
  • Protection for oil overheating
  • Pressure control map over pressure regulating valve
  • Specific injection pressure limiter
  • Specific injection pressure limiter 2
  • Specific injection pressure limiter 3
  • Relative permissible torque from the pedal position in torque limitation
  • Specific injection pressure
  • Specific injection pressure 2
  • Specific injection pressure - cold correction
  • Driver torque request
  • Driver torque request - AT
  • Driver torque request for reverse gear
  • CAT downstream temperature sensor characterization
  • CAT upstream temperature sensor characterization
  • DPF downstream temperature sensor characterization
  • Turbo upstream temperature sensor characterization
  • Torque limiter for the 1st gear selected
  • Torque limiter for the 2nd gear selected
  • Torque limiter for the 3rd gear selected
  • Torque limiter for the 4th gear selected
  • Torque limiter for the 5th gear selected
  • Torque limiter for the 6th gear selected
  • Torque limiter for the 7th gear selected
  • Torque limiter for the 8th gear selected
  • Torque limiter for the 9th gear selected
  • Torque limiter for for reverse gear
  • Torque limiter for the APS/BPS
  • Torque limiter for the APS/BPS 2
  • Variable geometry duty cycle limit
  • Variable geometry duty cycle limit 2
  • Variable geometry duty cycle limit 3

Programinės įrangos identifikatoriai (9)

Aparatinės įrangos Nr.Programinės įrangos Nr. (lustas)VersijaAtnaujinimo programinė įrangaECU
1.94.0247P5907401H 0004 BOSCH EDC17CP44
1.00.0207P5907401G 0003 BOSCH EDC17CP44
1.00.0207P5907401K 0003 BOSCH EDC17CP44
1.00.0267P5907401D 0004 BOSCH EDC17CP44
1.00.0287P5907401D 0002 BOSCH EDC17CP44
1.00.0217P5907401E 0004 BOSCH EDC17CP44
1.94.0397P5907401D 0001 BOSCH EDC17CP44
1.00.0257P5907401R 0001 BOSCH EDC17CP44
1.00.0377P5907401D 0003 BOSCH EDC17CP44

ECU pastabos

MICRO Infineon Tricore TC1797 This setting file can be used with the New Genius, the protocol supports identification and writing only. IF the matching original file is already present in databank it can be used for the modification and the writing operation. To work on this ECU you can use NewTrasdata
MICRO Infineon Tricore TC1797 This setting file can be used with the New Genius, the protocol supports identification and writing only. IF the matching original file is already present in databank it can be used for the modification and the writing operation.