CLAAS ARION 470 4.5L 114kW/153HP MD1CE101

ECU BOSCH MD1CE101 · 155 CV (114 kW) · 4500 cc · Diesel sovralimentato

ECU duomenų bazėCLAAS › CLAAS ARION 470 4.5L 114kW/153HP MD1CE101

Raskite programinės įrangos identifikatorius (aparatinės, programinės įrangos ir atnaujinimo numerius), galimas derinimo parinktis ir kaip gauti originalų arba perprogramuotą failą.

✓ Derinimas failu (flash) 3 programinės įrangos versijos

Transporto priemonės duomenys

MarkėCLAAS
ModelisARION
Variklis470 4.5L 114kW/153HP MD1CE101
Serijinė galia155 CV / 114 kW
Darbinis tūris4500 cc
KurasDiesel sovralimentato
Transporto priemonės tipasTractor

ECU

GamintojasBOSCH
ModelisMD1CE101
Atmintis / EPROMMicro Infineon TRICORE categoria AURIX. Il micro ha una DFLASH da 848 Kbyte

Galimos derinimo operacijos / parinktys:

  • Boost pressure limiter
  • Boost pressure
  • Displacement
  • Maximum torque limitation at clutch
  • Maximum torque limitation at clutch 2
  • Desired fuel quantity map for open loop
  • Exhaust gas temperature
  • Exhaust gas temperature 2
  • Engine reference power at crankshaft
  • Max CAT temperature threshold for component protection
  • Basic torque management at engine cranking
  • Injection period
  • Injection period 2
  • Injection opening time related to inj. pressure
  • Injection mass at high temperature
  • Injection mass at low temperature
  • Maximum fuel quantity for turbine overspeed prevention
  • Injection limit - turbocharger protection
  • Max injection limit
  • Fuel quantity limitation after cold start
  • L
  • Torque limiter
  • Torque limiter for diagnostic
  • PTO torque limiter
  • Torque limiter during particulate filter overloading - pressure
  • Lambda value of the smoke limitation
  • MAP - limp home mode
  • Maximum absolute effective torque
  • Maximum indicated torque
  • Maximum engine torque at crank shaft
  • Maximum engine power
  • Max torque profile
  • Injection quantity for engine overheating protection
  • Injection quantity for engine overheating protection 2
  • Pressure control map over pressure regulating valve
  • Specific injection pressure limiter
  • Specific injection pressure limiter 2
  • Specific injection pressure limiter 3
  • Specific injection pressure limiter for diagnostics
  • Specific injection pressure limiter for EFT sensor
  • Specific injection pressure
  • Specific injection pressure 2
  • Driver torque request at the start
  • CAT downstream temperature sensor characterization
  • CAT upstream temperature sensor characterization
  • DPF downstream temperature sensor characterization
  • DPF upstream temperature sensor characterization
  • SCR downstream temperature sensor characterization
  • SCR upstream temperature sensor characterization
  • Turbo upstream temperature sensor characterization
  • Torque limiter for for reverse gear
  • Torque limiter for EFT sensor
  • Torque limiter in recovery mode
  • Torque limiter in recovery mode 2
  • Torque limiter in recovery mode 3
  • Torque limiter in recovery mode 4
  • Torque model - torque to fuel quantity conversion
  • Torque model for performance limiter
  • Torque model with performance limiter stage 1 is active
  • Torque model with performance limiter stage 2 active
  • Torque model with performance limiter after coldstart 1 active
  • Torque model with performance limiter after coldstart 2 active
  • Turbocharger volumetric efficiency

Programinės įrangos identifikatoriai (3)

Aparatinės įrangos Nr.Programinės įrangos Nr. (lustas)VersijaAtnaujinimo programinė įrangaECU
P_1603 4.5.6 1.67.012g1ojg805_rcd BOSCH MD1CE101
P_1603 4.5.6 1.67.007g1ojg804_rcd BOSCH MD1CE101
P_1603 4.5.4 1.67.009g1ojgt06_rcc BOSCH MD1CE101

ECU pastabos

Micro Infineon Tricore TC299TP This Setting File can be used for serial system NewGenius. To work on this ECU you can use NewTrasdata