CLAAS ARION 440 4.5L 86kW/115HP MD1CE101

ECU BOSCH MD1CE101 · 117 CV (86 kW) · 4500 cc · Diesel sovralimentato

ECU duomenų bazėCLAAS › CLAAS ARION 440 4.5L 86kW/115HP MD1CE101

Raskite programinės įrangos identifikatorius (aparatinės, programinės įrangos ir atnaujinimo numerius), galimas derinimo parinktis ir kaip gauti originalų arba perprogramuotą failą.

✓ Derinimas failu (flash) 5 programinės įrangos versijos

Transporto priemonės duomenys

MarkėCLAAS
ModelisARION
Variklis440 4.5L 86kW/115HP MD1CE101
Serijinė galia117 CV / 86 kW
Darbinis tūris4500 cc
KurasDiesel sovralimentato
Transporto priemonės tipasTractor

ECU

GamintojasBOSCH
ModelisMD1CE101
Atmintis / EPROMMicro Infineon TRICORE categoria AURIX. Il micro ha una DFLASH da 848 Kbyte

Galimos derinimo operacijos / parinktys:

  • Boost pressure limiter
  • Boost pressure
  • Displacement
  • Maximum torque limitation at clutch
  • Maximum torque limitation at clutch 2
  • Desired fuel quantity map for open loop
  • Exhaust gas temperature
  • Exhaust gas temperature 2
  • Engine reference power at crankshaft
  • Max CAT temperature threshold for component protection
  • Basic torque management at engine cranking
  • Injection period
  • Injection period 2
  • Injection opening time related to inj. pressure
  • Injection mass at high temperature
  • Injection mass at low temperature
  • Maximum fuel quantity for turbine overspeed prevention
  • Injection limit - turbocharger protection
  • Max injection limit
  • Fuel quantity limitation after cold start
  • L
  • Torque limiter
  • Torque limiter for diagnostic
  • PTO torque limiter
  • Torque limiter during particulate filter overloading - pressure
  • Lambda value of the smoke limitation
  • MAP - limp home mode
  • Maximum absolute effective torque
  • Maximum indicated torque
  • Maximum engine torque at crank shaft
  • Maximum engine power
  • Max torque profile
  • Injection quantity for engine overheating protection
  • Injection quantity for engine overheating protection 2
  • Pressure control map over pressure regulating valve
  • Specific injection pressure limiter
  • Specific injection pressure limiter 2
  • Specific injection pressure limiter 3
  • Specific injection pressure limiter for diagnostics
  • Specific injection pressure limiter for EFT sensor
  • Specific injection pressure
  • Specific injection pressure 2
  • Driver torque request at the start
  • CAT downstream temperature sensor characterization
  • CAT upstream temperature sensor characterization
  • DPF downstream temperature sensor characterization
  • DPF upstream temperature sensor characterization
  • SCR downstream temperature sensor characterization
  • SCR upstream temperature sensor characterization
  • Turbo upstream temperature sensor characterization
  • Torque limiter for for reverse gear
  • Torque limiter for EFT sensor
  • Torque limiter in recovery mode
  • Torque limiter in recovery mode 2
  • Torque limiter in recovery mode 3
  • Torque limiter in recovery mode 4
  • Torque model - torque to fuel quantity conversion
  • Torque model for performance limiter
  • Torque model with performance limiter stage 1 is active
  • Torque model with performance limiter stage 2 active
  • Torque model with performance limiter after coldstart 1 active
  • Torque model with performance limiter after coldstart 2 active
  • Turbocharger volumetric efficiency

Programinės įrangos identifikatoriai (5)

Aparatinės įrangos Nr.Programinės įrangos Nr. (lustas)VersijaAtnaujinimo programinė įrangaECU
P_1603 4.5.6 1.67.013g1ocg805_rcd BOSCH MD1CE101
P_1603 4.5.4 1.67.015g1ocgt06_rcc BOSCH MD1CE101
P_1603 4.5.4 1.67.011g1owgt06_rcc BOSCH MD1CE101
P_1603 4.5.6 1.67.011g1ocg804_rcd BOSCH MD1CE101
P_1603 4.5.6 1.67.009g1owg804_rcd BOSCH MD1CE101

ECU pastabos

Micro Infineon Tricore TC299TP To work on this ECU you can use NewTrasdata This Setting File can be used for serial system NewGenius.
Micro Infineon Tricore TC299TP This Setting File can be used for serial system NewGenius. To work on this ECU you can use NewTrasdata