RENAULT KANGOO 2 1.5L 8V dCi 81kW/109HP SID310
ECU CONTINENTAL-SIEMENS-VDO SID310 · 110 CV (81 kW) · 1500 cc · Diesel sovralimentato
ECU duomenų bazė ›
RENAULT › RENAULT KANGOO 2 1.5L 8V dCi 81kW/109HP SID310
Raskite programinės įrangos identifikatorius (aparatinės, programinės įrangos ir atnaujinimo numerius), galimas derinimo parinktis ir kaip gauti originalų arba perprogramuotą failą.
✓ Derinimas failu (flash)
✓ Galimas papildomas modulis 8 programinės įrangos versijos
Gaukite failą šiai transporto priemonei
Transporto priemonės duomenys
| Markė | RENAULT |
| Modelis | KANGOO 2 |
| Variklis | 1.5L 8V dCi 81kW/109HP SID310 |
| Serijinė galia | 110 CV / 81 kW |
| Darbinis tūris | 1500 cc |
| Kuras | Diesel sovralimentato |
| Transporto priemonės tipas | LCV |
ECU
| Gamintojas | CONTINENTAL-SIEMENS-VDO |
| Modelis | SID310 |
| Atmintis / EPROM | MICRO INFINEON TRICORE - 24576 - 300000 |
Galimos derinimo operacijos / parinktys:
- Boost pressure limiter for diagnostics
- Boost pressure limiter
- BAP setpoint limitation depending on before particulate filter pressure in aftertreatment modes
- Boost pressure in aftertreatment modes
- Boost pressure in regular injection mode
- Maximum torque limitation at clutch
- Calibration of high value threshold for CSF upstream temperature overheat failure
- Effective engine torque setpoint
- Effective engine torque setpoint for safety
- Max accepted exhaust gas temperature value before turbine
- Exhaust gas temperature value before turbine in regeneration mode
- Exhaust gas temperature value before turbine in regular injection mode
- Engine torque limit for transmission protection
- Max torque correction factor for APS sensor
- Max torque correction factor for APS sensor in aftertreatment modes
- Max torque correction factor for IAT sensor
- Max torque correction factor for IAT sensor in aftertreatment modes
- Basic torque management at engine cranking
- Gearbox torque threshold variation
- Injection period
- Injection opening time related to inj. pressure
- Maximum injection quantity in aftertreatment modes
- Torque limiter for diagnostic
- Torque limiter in full load
- Maximum absolute effective torque
- Maximum absolute effective torque in ECO mode
- Maximum indicated torque
- Maximum indicated torque in regeneration mode
- Max exhaust gas temperature value before turbine in regeneration mode
- Max exhaust gas temperature value before turbine in regular injection mode
- Maximum particulate filter upstream temperature for diagnosis
- Maximum temperature upstream of the turbine during DeNOx regeneration
- Maximum temperature upstream of the turbine during DeSOx regeneration
- Main torque model during regular combustion mode
- Maximum temperature authorized in rich conditions
- Specific injection pressure limiter
- Specific injection pressure limiter in aftertreatment modes
- Maximum pressure ratio limit depending on temperature
- Specific injection pressure
- Specific injection pressure in aftertreatment modes
- Mass air flow - gear 1 (N or R)
- Mass air flow - gear 2
- Mass air flow - gear 3
- Air mass flow
- Mass air flow - gear 5
- Mass air flow - gear 6
- Air mass flow in aftertreatment modes
- Maximum temperature before oxidation
- Maximum temperature before turbine for diagnosis
- Temperature before turbine setpoint during npu, spu and injection mode
- Mean temperature desired downstream of the NOx-trap
- Torque limiter for EFT sensor
- Torque limiter for intake manifold pressure
- Torque limiter for intake manifold pressure in regeneration mode
- Torque model - fuel quantity to torque conversion
- Torque model - fuel quantity to torque conversion in aftertreatment modes
- Torque model - fuel quantity to torque conversion - particulate regeneration mode
- Torque model - torque to fuel quantity conversion - particulate regeneration mode
Programinės įrangos identifikatoriai (8)
| Aparatinės įrangos Nr. | Programinės įrangos Nr. (lustas) | Versija | Atnaujinimo programinė įranga | ECU |
|---|---|---|---|---|
| 6680R | 8985R | 1.83.004 | 1771S | CONTINENTAL-SIEMENS-VDO SID310 |
| 6680R | 7384R | 1.83.013 | 8213R | CONTINENTAL-SIEMENS-VDO SID310 |
| 6680R | 0451S | 1.83.009 | 1343S | CONTINENTAL-SIEMENS-VDO SID310 |
| 6680R | 8985R | 1.00.021 | 0556S | CONTINENTAL-SIEMENS-VDO SID310 |
| 6680R | 0451S | 1.83.014 | 1771S | CONTINENTAL-SIEMENS-VDO SID310 |
| 6680R | 7384R | 1.83.017 | 1773S | CONTINENTAL-SIEMENS-VDO SID310 |
| 6680R | 7384R | 1.83.006 | 7385R | CONTINENTAL-SIEMENS-VDO SID310 |
| 7137R | 6677R | 1.83.010 | 8682R | CONTINENTAL-SIEMENS-VDO SID310 |
ECU pastabos
MICRO Infineon Tricore TC1791 This Setting File can be used for serial system NewGenius. To work on this ECU you can use NewTrasdata
Galimi papildomi moduliai
A plug-and-play add-on module is available for this vehicle (as an alternative or in addition to the file):